P410i firmware offline. 64 the latest) I remember that I downloaded and ran a SPP iso to update my G8, is this the way to update also the P410? Sep 2, 2022 · HPE Smart Array P410 Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Once the erase is completed the drive needs to reenabled. For more information on any of these components, click the Browse FW CD command from the Mar 25, 2010 · "Firmware CD Supplemental Update / Online ROM Flash Component for Linux - HP Smart Array P812 version 3. 5 listed as a supported OS) but that process fails with issues like: Running the raw . 5" SAS. 0 and 2. Jun 4, 2012 · The HP Array Configuration Utility is a web-based application that helps you configure HP ProLiant SMART-2 Array Controllers, HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers. What is the actual purpose and use of the the HP SMH software? Would sure like to have someway to get notification of a drive or array failure without having to install a third party software like PRTG. HPE SSA will allow you to configure and manage your storage as before, but now with additional features, abilities, and supported devices. com/servers/spp/download. Nov 12, 2016 · Micromax Funbook P410 Firmware. Few days ago I installed Hitachi (HGST) Ultrastar 7K6000 6TB 7200rpm 128MB HUS726060AL5214 0F22811 3. Firmware Dependency: A minimum FW version 3. 1. Firmware v5. Government under vendor’s standard commercial license. The low profile, half height card has 8 ports and utilizes DDR2-800 memory. S. 0 or later. You can use the Array Configuration Utility for several tasks such as configuring the array controller initially, adding disk drives Feb 19, 2019 · In the search type “HPE Smart Array P420i Controller”, select “Software Type: Firmware” and “Software Version: Drive Controller”. Oct 20, 2025 · You can use ssacli (smart storage administrator command line interface) tool to manage any of supported HP Smart Array Controllers in your Proxmox host without need to reboot your server to access Smart Storage Administrator in BIOS. HPE Smart Array Advanced Pack 1. Apr 6, 2015 · This x64 Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 Oct 28, 2013 · Get the latest official Hewlett Packard (HP) Smart Array P410i Controller storage controller drivers for Windows 11, 10, 8. This project requires a K8s distributed storage … We would like to show you a description here but the site won’t allow us. scexe). I have HP DL120 G7, P410. You can use the Array Configuration Utility for several tasks such as configuring the array controller initially, adding disk drives May 28, 2020 · Only offline firmware flashing of drives is supported for these configurations. 66 from from 2011 and your disks also need attention because they're on HPD2 from 2009. Your Smart Array P410 is using firmware version 3. Clearly a case of the OS not supporting the patch script. Feb 19, 2013 · This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m Product Bulletin, Research or buy HP printers, desktops, laptops, servers, storage, enterprise solutions and more at the Official Hewlett-Packard Website Dec 29, 2000 · After installing my P410 into my N40L MicroServer I also was able to install the Array Configuration Utility (ACU) without installing HP SMH. Applies to SAN/iQ 9. Examine the arrays and you’ll be able to determine if the data is salvageable. You are viewing the most relevant and current results for this product. 10 FW on your HP SAS Expander Card. 0 features are now part of the baseline features of HPE SSA, with the appropriate firmware. You can use the Array Configuration Utility for several tasks such as configuring the array controller initially, adding disk drives Software DetailsCommunication error, please retry or reload the page I’m thinking SSDs and GPU firmware updates can be beneficial. This document is for the person who installs, administers, and troubleshoots servers and storage systems. 66 is required on your HP Smart Array controller when updating to 2. Update drivers using the largest database. 23. In the case of MTK, you need to use the SP Flash tool to flash the software. May 23, 2020 · Enable IT mode on HP Smart Array P410i RAID card on HP DL380 Gen7 servers Recently my job requires me to build a testbed platform for a new project. 5) using the downloaded standalone driver from HP (which has ESXi 5. scexe) supersedes "Firmware CD Supplemental Update / Online ROM Flash Component for Linux - Smart Array P212, P410, P410i, P411, P712m, and P812 version 2. The recovery ROM provides protection against power outages during firmware flashing. Where can I get a code? HPE Smart Array P410 Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Feb 13, 2019 · For the test, I will update the Smart Array P410 firmware on the HP ProLiant DL180 G6 server. Firmware Maintenance CD version 8. The HP Smart Array P410 is an 8 Port Serial Attached SCSI (SAS) RAID controller. 74 (B)" (CP012446. I must say I'm not using HP hardware to test it, but rather a Dell motherboard. Hi, I got a brand new DL380p gen8 Server with 8 300GB SAS disks in 2 raid 5, and installed esxi from the branded image: VMware-ESXi-5. Is there a gui method to easily update firmware? Edit: Thanks, Looks like the most easiest rookie solution is usb install of windows without even registering/buying windows and use it to update device firmware. When I use the card with the cache module and battery attached, it gives me a failure message and doesn't go any further. Online drive firmware update available for Smart Array Controllers configured in systems running supported Linux, Microsoft Windows, and VMware environments. My OS is WHS 2011. Enhancements/New Features: For more information about updating the firmware, see the HP ProLiant Storage Firmware Maintenance User Guide (for controller and drive firmware) or the HP Online ROM Flash User Guide (for server firmware). Not sure if there’s a way to bypass this, however bypassing the process could result in undesired results. Download the official Micromax P410i Stock Firmware ROM (flash file) for your Micromax Device. I cannot configure the RAID on my P410i, and the only reason I can imagine is the RAID Controller License. iso on the first raid. 06 (not sure, 5. The HPE Smart Storage Administrator (HPE SSA) is a web-based application that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HPE Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. 10 (C): When the HP SAS Expander was unresponsive, the attached HP Smart Array P410 or P410i Controller was not allowed to discover drives that were attached. 09/24/2025 P-touch Editor6. Download HPE SSA software and explore its features, user guide and quickspecs. 14. The P410 is ideal for RAID 0, 1, 1+0, 5, 5+0 and can be upgraded with a minimum 256MB cache module, battery kit (for BBWC),and Smart Array Advanced Pack license key for RAID 6 (ADG), & 6+0. Currently, there are two different methods for updating firmware on HPE servers and options: the traditional Offline ROM Flash, and the innovative Online ROM Flash. Consistent with FAR 12. MT77_MD7062HC8W1. That means no host downtime when managing your storage. The rx2800 i4 and DL380 G6 list different P410i firmware versions, however the install packages do BIOS checks before allowing you to continue. This x64 Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 Jun 2, 2017 · We have just received two used HP ProLiant servers for community use and I need advice on where to find offline firmware update ISOs like those from Dell repositories. May 4, 2020 · Good Evening Unraiders, I am an owner of an HP ProLiant DL380 Gen 7 Original configuration: 2 x Intel Xeon CPU X5660 6 Core 32 GB ECC Ram P410i Smart Array RAID controller 1x 4 TB Mechanical Parity HDD 6 x 1 TB SSD (Various Makes and Models) - Yes I know it is not currently supported by Unraid. We can access it during the the server boot time to configure the disk arrays Confidential computer software. The P410 is designed for RAID applications and can be upgraded with the 512MB battery-backed write cache (BBWC) or 512MB / 1GB flash-backed write cache (FBWC) and the Smart Array Advanced Pack. The P410 is ideal for RAID 0, 1, 1+0, 5, 5+0 and can be upgraded with a minimum 256MB cache module, battery kit (for BBWC), Flash Backed Write Cache (FBWC), and Smart Array Advanced Pack license key for This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, P712m, and P812 Oct 22, 2009 · Offline Smart Component which upgrades the firmware on HP SAS Expander Card. This for backup, only 1 HDD in volume, RAID0. hpe. Mar 30, 2014 · HPE Smart Array Advanced Pack 1. Important: Important Notes: Only offline firmware flashing of drives is supported for these configurations. 74 and set up to use Automatic Server Recovery. There is a built-in tool for managing the Smart Array Controller in HPE Proliant servers. Where did you get this equipment?!? Jun 12, 2019 · If not, it may be that the P410i has simply disabled access to the RAID0 in an overabundance of caution. I have uploaded the machines Active Health System How can I update the SmartArray P410i firmware on a DL360G6? The usual method via SPP Roel Van de Paar 196K subscribers Subscribe Nov 25, 2018 · HPE Smart Array Controller The HPE Smart Array Controller provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and data protection for HPE ProLiant rack and tower servers. It also provides information on parts, troubleshooting, diagnosing server issues, and how to remove and replace server components. Some ACU CLI features are only available in the offline environment, such as setting the boot controller and boot volume. 212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U. A Jun 22, 2011 · The HP Offline Array Configuration Utility provides an ISO image that can be mounted, burned to a CD/DVD, or flashed to a USB memory key or SD card by using the HP USB Key Utility for Windows. HPE SSA replaces Mar 21, 2018 · Moreover sometimes very bad things can happen with RAID 10 configuration on to disks, especially with ancient version of firmware on P410i (5. CLI is not as convenient as GUI interface provided by BIOS or desktop utilities, but still allows you to Aug 3, 2013 · I installed an HP P410 RAID controller in my HP N40L ProLiant MicroServer. Problems Fixed in version 2. Apr 11, 2013 · This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 HP Smart Array P410 Controller The HP Smart Array P410 is an 8 Port Serial Attached SCSI (SAS) RAID controller. For more information on this deliverable go to www. Simplify software management with HPE SUM. One of the main uses in the new BL8x0C i2 server is to change the P410 built in controller from HBA to RAID mode. Feb 19, 2013 · This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m Feb 19, 2013 · This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, P712m and P812 This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, P712m and P812 Feb 19, 2013 · This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m The HP Smart Array P410 is HP's PCI Express (PCIe) 2. Examples: Feb 19, 2013 · This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m Platforms like PDP, VAX, and Alpha employ a firmware-based BIOS where you could boot the system with commands like "b dua0" to boot from disk dua0 All modern computers, including Itanium, now employ a firmware-software-hybrid technology, known as UEFI, which executed by an internal management processor (some sort of x86 thingy that is always running as long as power supply available, even if Jul 9, 2017 · What is the recommended method of testing individual drives in a HP SmartArray P410 logical device? We have 8 300gb SAS drives in a RAID 10 configuration and I suspect that one of the drives may be failing. x 11 / 10 / 10x64 09/17/2025 P-touch Update Software 11 / 10 / 10x64 09/16/2025 Software/Document Installer (Recommended) 11 / 10 / 10x64 We would like to show you a description here but the site won’t allow us. Feb 19, 2013 · This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 HP Integrity Server - How to use SAUPDATE EFI Utility from the ILO Virtual Media Information The SAUPDATE. The RAID controller is refusing to recognize inserted drives as an array. When the HP SAS Expander was unresponsive, the attached HP Smart Array P410 or P410i Controller was not allowed to discover drives that were attached. Dec 9, 2009 · This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m Abstract This document identifies, and provides instructions for, the array configuration tools available for HP ProLiant controller and server products. 10 (C): Oct 29, 2014 · In order to flash your MICROMAX Funbook P410i you need to check out either your device is using MTK (the firmware name should contain "MT") or Qualcomm chipset (the firmware name should contain "MSM"). The boot does not complete Offline Smart Component which upgrades the firmware on HP SAS Expander Card. EFI utility from the ILO Virtual Media feature to update the firmware of SAS controllers and change the mode of the P410i controller from HBA mode to Raid mode. Everything seems to be working fine but I get a warning for the Smart Array P420i controller in the Hardware Health Status. If you do not touch controller and disks they work. for more information, just Feb 19, 2013 · This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m Apr 6, 2015 · This x64 Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 Oct 24, 2016 · This x64 Smart Component provides firmware for the following storage controllers: Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 This document provides system information, server specifications, and installation procedures for the HP Integrity rx2800 i4 Server. We also provide ROM for other Micromax Devices for free. First step is to replace the battery and reboot the server to the offline array configuration utility. Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. I've just installed an HP SmartArray P410 controller into my HP ProLiant DL320G6 server. 00" (CP012783. This user guide explains how to use the SAUPDATE. The story so far This server (our file s Simplify storage management with HPE SSA (Smart Storage Administrator) software. 1, 8, or 7. EFI utility is used in order to show and update the firmware an SAS controllers like the P400, P800, P700, P410 etc. This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m May 30, 2020 · I'm trying to make this P410 work, but it behaves strangely. 211 and 12. The P410 is designed for RAID applications and can be upgraded with the 512MB battery-backed write cache (BBWC) or 512MB / 1GB flash-backed write cache (FBWC) and the Smart Dec 6, 2019 · Trying to bring my HP 380G7 back on line after a major hardware failure. 70 Contents This table lists all of the firmware components on this Firmware Maintenance CD. (My background is Dell) The This table lists all of the software and firmware on this Service Pack for ProLiant. Any ProLiant server configured with a Smart Array P410 or Smart Array P410i Controller running Smart Array Firmware Version 2. . In the P410 manual it talks about using HP Systems This video showing how we can update BIOS and firmware in an HP Proliant Server (Gen 9 + Gen 10). The controller seems detected by the server BIOS (it shows up in controllers list in the BIOS set-up), hard PProLiantDL320G6 5p HPProLiantDL320s HPProLiantDL360G4 HPProLiantDL360GP 4 p This bundle contains the Smart Update Manager (SUM) application with the firmware for HPE Integrity BL860c/BL870c/BL890c i4 Servers (System firmware (SFW), FPGA firmware, iLO-3 MP firmware & Power Monitor, I/O and HDD firmware). We would like to show you a description here but the site won’t allow us. donarachchi2 (donarachchi2) June 12, 2019, 9:01am 5 Oct 28, 2013 · Get the latest official Hewlett Packard (HP) Smart Array P410 Controller storage controller drivers for Windows 11, 10, 8. HDD Firmware Version: C7J0. Make a bootable USB using HP usb key utility and start server from USB. 64. Valid license from HP required for possession, use or copying. If no argument is specified for "erasepattern" by default "random_random_zero" will be selected. The server does not have Windows installed (Xenserver) - I’ve made use of a Linux utility (badblocks) to test but as the drives in the array is RAID1 I am not sure if badblocks tests This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m HPE Smart Array P420i Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. 20131206 Best Regards Rahul_Bhutani Easily download HPE Smart Update Manager (SUM) for streamlined server updates. scexe has similar issues. I do not ever remember this issue. Feb 28, 2017 · 1 Spice up Topic Replies Views Activity HPE P420 - 1783 Slot 2 Drive Array Controller Failure Hardware & Infrastructure hpe-hardware , question 6 1386 August 22, 2022 6i array controller won't initialize on Proliant DL380 G4 Hardware & Infrastructure hp-hardware , question 10 196 August 8, 2011 HP ML350Gen9 LFF Smart Array P840 - RAID10 total failure out of the blue Hardware & Infrastructure Feb 20, 2011 · Important: HPE SSA replaces the existing HP Array Configuration Utility, or ACU, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online. I have an HP ProLiant DL180 G5 server with a Smart Array E200 RAID controller. RAID5 is available on the SA P410/P410i with a minimum of 256MB cache and battery RAID 5+0: This is a RAID 0 array striped across 5 elements. May 24, 2013 · Product Bulletin, Research or buy HP printers, desktops, laptops, servers, storage, enterprise solutions and more at the Official Hewlett-Packard Website Aug 3, 2012 · SAN/iQ patch to deliver the latest HP Smart Array P410i Raid Controller firmware 5. In offline mode, users can configure or maintain detected and supported ProLiant devices, such as optional Smart Array controllers, integrated Smart Array controllers, and RAID Array controllers. something, it seems to be v6. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy B Utilities SAS disk setup Using the saupdate command The saupdate command is used to query or change the mode of the Smart Array P410i and Smart Array P411 controllers to HBA or RAID. Work fine. Explore price, features and quickspecs. xx or earlier): controller can lose both disks at one by issuing some internal command that wipes that content. If the active firmware image becomes corrupt, Smart Array controllers use the redundant firmware image and continue operating. P410 Firmware Version: 6. I checked ILO and everything is ok there. 0 Serial Attached SCSI (SAS) RAID controller. Jun 26, 2025 · Download Micromax P410i Stock Firmware Apr 11, 2016 · P410i HBA mode support was only released for Integrity servers. HP Smart Array P410 Controller The HP Smart Array P410 is HP's PCI Express (PCIe) 2. HPE SSA will allow you to configure and manage your Feb 19, 2013 · This Smart Component provides firmware for the following storage controllers: Smart Array P212, P410, P410i, P411, and P712m Apr 15, 2016 · 3 For information. Dec 7, 2012 · This package contains EFI applications to update the firmware for Smart Array (SAS) P410i for HPE Integrity rx2800 i4, rx2800 i6, rx2900 i4 and rx2900 i6 Servers. Aug 30, 2016 · This level of fault tolerance can withstand a single drive failure without downtime or data loss. 34. Recovery ROM HP Smart Array controllers store a redundant copy of the controller firmware image to protect against data corruption. 0-799733-HP-5. So far I've tried to update it from the OS (ESXi 5. NOTE: Firmware takes a physical drive offline whenever an erase is queued or running. Combines the straight block-level striping of RAID 0 with the distributed parity of RAID 5. All other OSes would require an offline update using the Service Pack for ProLiant and Smart Update Manager. But I see no way of getting notification of a drive failure other than having to manually open the HP Array Configuration Utility software yourself. vg8 qi82ercl i0w xzggx r8 efwq 3edlrj 4d5aq zcj8y am